Beijing Tianyihongda Science & Technology Development Co., LTD

Sincerity Is Fundamental, Clients Is The First. Strict Quality Control, Earnest Service Supply.

Manufacturer from China
Site Member
7 Years
Home / Products / Power Distribution Terminal /

Counter Current Value Remote Control Terminal , HV Switch Control Remote Control Feeder

Contact Now
Beijing Tianyihongda Science & Technology Development Co., LTD
City:beijing
Province/State:beijing
Country/Region:china
Contact Now

Counter Current Value Remote Control Terminal , HV Switch Control Remote Control Feeder

Ask Latest Price
Video Channel
Brand Name :Tianyihongda
Model Number :TYHD-FTU16
Certification :type test report
Place of Origin :Beijing,China
MOQ :1set(3pcs)
Price :Negotiation
Payment Terms :L/C, T/T, Western Union
Supply Ability :1000 sets per month
Delivery Time :within 3-5 working days
Packaging Details :standard export package
Lockout Delay :0.00-600.00S;Post acceleration time
IN> Amp Value :0.001-10*In;Zero-sequence current
Current Value :0.1*In-10*In;Counter current value
Lockout Open :30-600S;Lockout open retention time after Y-time delay successfully closes
HarmonicComponent :0.0-100.0% harmonic content
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

new HV switch control device equippeddirecte exchange sampling and damp-proff

During the application, if there is any unknown situation, please find out the cause and solve the problem according to the following table.

No. Phenomenon Causes Handling methods
The device power supply is abnormal.

1. Check if the aviation plug wires are solidly connected?

2. Check if the device and the aviation plugs at both sides of the switch are solidly connected? Check if the wiring is correct?

1. Reconnect the aviation plug and screw it tightly.

2. Reinsert the aviation plugs at both sides and screw them. Rewire according to the wiring diagram.

The opening and closing of the switch cannot be operated on the device panel.

1. Check if the "local/remote" toggle switch is right?

2. Check the operating status (manual or automatic) of the switch?

3. Check if the switch is in a lockout status?

1. Turn the toggle switch to "local".

2. Check the opening and closing indicator of the switch.

3. Manually remove the switch lockout.

Override trip or false action of the switch Check if the parameter setting of the device is right? Reset the parameters according to the actual circuit and the superior and inferior switches.
Opening or closing fault of the small remote controller

1. Check if the remote controller number at the bottom of the device case cover is consistent with the number of the small remote controller?

2. Check if the battery is installed and well contacted?

3. Check if the red indicator of the remote controller is on while operating the small remote controller?

4. Check if the toggle switch is turned to “local”?

1. Use the small remote controller with the same number as the device.

2. Re-install the battery.

3. The battery can be replaced if the indicator is off.

4. Turn the toggle switch to “local”.

Preparation before Installation

Because the installation positions and methods are different, the users shall prepare the installation fittings by themselves before installation according to the sizes of mounting holes and the installation methods.

Note: Please refer to the installation dimension drawing attached to this manual for the detailed sizes of mounting holes and installation methods.

Modifying Fixed Value

After entering fixed value interface, press “ENT” to confirm the fixed value item and press “ENT” again to confirm the modification of fixed value. Press number buttons “0” to “9” to input the fixed value parameters. Press “” or “” to change the data position and press “SET” to save the fixed value (Press “ESC” to give up the modification and the fixed value after modification will not be saved).

After entering fixed value interface, press “” or “” to switch the fixed value interfaces.

After entering fixed value interface, press “ESC” to exit to the main menu.

Check Event Records

The smaller the record number is, the newer the event will be. The occurring time of event No.4 is earlier than that of event No.2.

While checking the record, press “” to check the last event and press “” to check the next event.

While checking the record, press “ESC” to exit to the main menu.

Modify System Time

The method to modify the system time is the same as that of modifying fixed value. No further description will be given here.

Check Content

In corresponding interface, press “” or “” to switch different content.

Press “ESC” to exit.


Inquiry Cart 0
You May Like
DTU Network Feeder Power Distribution Terminal Automation Device High Performance
DTU Network Feeder Power Distribution Terminal Automation Device High Performance
DTU Power Remote Transmission Unit , High Stability Network Termination Unit 
DTU Power Remote Transmission Unit , High Stability Network Termination Unit 
High Frequency Power Distribution Terminal 18 Lines Remote Control Self Check
High Frequency Power Distribution Terminal 18 Lines Remote Control Self Check
High Speed Digital Signal Processing System For Connecting Circuit Breaker On Pole
High Speed Digital Signal Processing System For Connecting Circuit Breaker On Pole
Wireless Transmission Power Distribution Terminal Feeder Unit For Circuit Breaker
Wireless Transmission Power Distribution Terminal Feeder Unit For Circuit Breaker
Software Platform Dsp Digital Signal Processor Self Test With Channel Monitor
Software Platform Dsp Digital Signal Processor Self Test With Channel Monitor
High Performance Master Terminal Unit TYHD - DTU Model Communication Solutions
High Performance Master Terminal Unit TYHD - DTU Model Communication Solutions
DTU Real Time Power Distribution Terminal For Data Storage / Recording
DTU Real Time Power Distribution Terminal For Data Storage / Recording
Fast / Stable Rtu Scada Power Systems For Power Circuit Low Power Consumption
Fast / Stable Rtu Scada Power Systems For Power Circuit Low Power Consumption
High Stability / Reliability Power Distribution Terminal With Channel Monitor
High Stability / Reliability Power Distribution Terminal With Channel Monitor
DTU Power Distribution Feeder For RMU , High Intensity Remote Interface Unit
DTU Power Distribution Feeder For RMU , High Intensity Remote Interface Unit
Fault Detection Power Distribution Terminal For Transmitting Measured Data
Fault Detection Power Distribution Terminal For Transmitting Measured Data
Strong Stability Power Distribution Terminal For Overhead Line Zero Sequence Reclosing
Strong Stability Power Distribution Terminal For Overhead Line Zero Sequence Reclosing
Damp Proof Remote Telemetry Unit , HV Switch Controller Electric Feeder Unit
Damp Proof Remote Telemetry Unit , HV Switch Controller Electric Feeder Unit
Automatic Power Distribution Terminal For All The Protections 1.5 Times Fixed Value
Automatic Power Distribution Terminal For All The Protections 1.5 Times Fixed Value